Step | | Procedure & Parts & Tools |
1 |
|
RAISE THE TANK COVER
|
2 |
|
PROP THE TANK WITH THE PROP ROD
|
6 |
|
USING A TORX WRENCH, REMOVE THE 3 SCREWS HOLDING THE INSIDE COVER NOTE: YOU WILL NEED TO PROP THE COVER BECAUSE ONE OF THE SCREWS BEING REMOVED HOLDS THE PROP ROD
Torx T30 |
|
|
7 |
|
PULL THE INSIDE COVER TO REMOVE IT
|
8 |
|
DISCONNECT THE WHITE CONNECTOR PLUG INSERT PROBES INTO THE CONNECTOR PLUG. RED PROBE TO RED WIRE AND BLACK PROBE TO BLACK WIRE. TURN UNIT ON. TURN VAC MOTOR ON. CHECK READING ON VOLT METER. VOLT METER SHOULD READ 24 VOLTS.
Volt meter (True RMS capable) |
|
|